HKED™

The Hybrid K-Edge/XRF Analyzer is designed to identify and quantify several heavy elements in homogeneous liquid or solid samples simultaneously. It has proven to give approximately the same measurement precision as destructive chemical analysis methods, yet is much simpler and faster to use. The instrument was developed at KFK Karlsruhe1, and is available from Mirion […]
InSpector™ 1000

The InSpector™ 1000 is a high-performance, hand-held NaI spectrometer for use primarily in first responder, customs, homeland security, and health-physics applications. One-click simplicity masks the sophisticated spectral processing facilities that lie within the instrument – providing a level of performance previously available only in more complicated laboratory systems. The InSpector 1000 is an instrument that […]
Clover™ Detectors

In the CLOVER detector assembly, the crystals are held on a minimized crystal holder to reduce the quantity of material surrounding the crystals and to improve peak to background ratio. The Features
Retractable™

Retractable cryostats provide a means of moving the detector element in relation to the sample with both under vacuum. The Features
X-PIPS™

X-PIPS™ 7-Element SDD Array is a spectroscopy sub-system sensitive to X-rays and low-energy gamma rays. It comprises of seven Silicon Drift Detectors (SDD) with a low noise CMOS reset type preamplifier, a HV bias supply and a cryogenic cooler. The Features
ESLB and ESLB-X

CANBERRA offers highly-reliable Silicon Lithium drifted detectors, cooled at cryogenic temperatures, for X-ray or conversion electron spectroscopy or beta decay exploration. Two configurations are available depending on the application. The ESLB is delivered with all components required for integration into an existing vacuum chamber. The ESLB-X comes with a complete cryostat and user friendly features […]
MAC

For applications requiring both portability and flexibility of use, the MAC (multi-attitude cryostat) is the answer. The unique fill and vent system employed by the MAC cryostat allows operation of the detector in any orientation without LN2 spillage even when the Dewar is full. The small size, lightweight, and ruggedness of the unit permit use […]
WM2110

The high resolution and wide dynamic range of its germanium detectors make the Model WM2110 system the choice for waste material containing totally unknown and/or complex mixtures, particularly when the samples contain both low energy and high energy nuclides. The Features
Auto Q2™

The system is designed to quantify plutonium and uranium in 200 L drums at levels below 10 nCi/g and at the same time perform plutonium isotopics measurements on drums containing less than 10 mg of plutonium. The Features
WM2500

Features are: